We are pleased to introduce you to our 32.768kHz crystal unit for F1XX, F2XX and F4XX:
For product information of "MSP430 series",
please see Texas Instruments' web site.
Please note: to design oscillation circuit for MSP430 series, you need to confirm the electronic characteristics as follows:
Oscillation allowance and Negative resistance (-R):
|
|
|

Please note: There is a trade-off between negative resistance and drive level.
| Product | Size [mm] | Applications | Images |
| MC-306 | 8×3.8×2.5t | Electronic, Gas, Water meter, Flow meter, Intelligent sensor, Measurement equipment, Blood pressure meter, Blood-sugar monitor, Security systems | ![]() |
| MC-146 | 7×1.5×1.4t | DSC, Consumer equipment, Radio equipment, Blood pressure meter, Blood-sugar monitor, Security systems | ![]() |
| FC-135 FC-13F |
3.2×1.5×0.8t 3.2×1.5×0.55t |
PMP, DSC, Portable equipment | ![]() |
| FC-12M | 2.0×1.2×0.6t | Portable equipment | ![]() |
![]() |
|||||||||||||||||||||
* Product Code: encoded numbers of crystal specifications |
|||||||||||||||||||||
![]() |
|||||||||||||||||||||
* Product Code: encoded numbers of crystal specifications |
|||||||||||||||||||||
![]() |
|||||||||||||
* Product Code: encoded numbers of crystal specifications |
|||||||||||||
| <Layout of XIN, XOUT, Crystal unit, Capacitor and Resistor> -Please lay out crystal unit, capacitor and resistor near MSP430 as far as possible. -Please connect XIN and XOUT within 20mm length, and do not cross other signal lines. |
|||||
|
|||||
| <GND Line Pattern and Interconnection of PCB> -Please lay out GND line pattern under crystal unit. -In case of muli-layered PCB board, do not lay out other signal lines under crystal unit. |
|||||
|